VirchueBio X v3.0 Free research beta · What’s new in v3.0

From a CT scan to thrombosis insight.

Drop in a CT or MR angiogram (DICOM): VirchueBio extracts the vessel, simulates its blood flow and shows where the vessel wall is most exposed to clot-promoting forces. Already have a vessel surface? Load its STL instead. VirchueBio X is a research platform from a University of Sydney team, free to use in your browser. Its rapid CFD module, ForgeFlow, solves the blood flow.

New here? The demo takes a built-in example from geometry to thrombosis number Θ in about a minute. Chrome or Edge on a desktop or laptop. Watch the getting-started video.

See the whole workflow

From a CT scan to a thrombosis map

A one-minute tour of the five steps, from dropping in a DICOM scan to the Θ map. The example is a synthetic scan, and run times depend on the vessel.

The whole workflow · 1 min 2 s · music, text on screenExample: a synthetic CT scan. Θ risk bands are proposed, not yet calibrated.
  • Research use onlyExploratory model results, not a medical device or a clinical risk score.
  • Your files stay with youScans, geometry and simulations are processed in your browser; nothing is uploaded unless you submit it.
  • Visible numerical statusMesh quality and flow convergence are shown alongside every result.

What the platform does

One workflow, from scan to wall loading

Four stages, each with its own checks, so you can see how far a result can be trusted before you share it.

01 — Scan

Extract the vessel

Drop a CT or MR angiography series (DICOM). The vessel is found slice by slice, bone and organs are removed, and its surface is built in millimetres, all in your browser.

02 — Geometry

Prepare the vessel

Review the extracted vessel, or import a fluid-lumen STL or a lumen with named caps. Confirm its units, review every opening and assign inlet and outlet roles.

03 — Flow

Simulate blood flow

Set flow and blood properties, generate a mesh with patient guidance and run a flow simulation with live progress and convergence checks. You can also let the vessel wall expand and recoil with each heartbeat (vessel wall motion).

04 — Thrombosis

Explore thrombosis maps

Compute the team's force-based thrombosis indices on the simulated flow, inspect them in 3D and export fields, figures and case records.

Start here

Three cases, from one minute to 45 minutes

New to the platform? Work through three built-in cases in order. Each takes longer than the one before, so you know what to expect before you run a vessel of your own.

Getting started · 2 min 46 s · no sound, captions on screenRecorded on VirchueBio X v1.0
  1. 1 · Easy

    Run the demo

    One click. The demo takes a pipe with a 50 % narrowing from geometry to thrombosis number Θ on a coarse mesh, and explains each step as it goes.

    Cells
    6,638
    Iterations
    607
    Run time
    about 1 min
    Run the demo →
  2. 2 · Medium

    The same pipe, step by step

    Do each step yourself. Choose Pipe stenosis in panel 1, set the mesh to 30,000 target cells in panel 2, generate the mesh and press Run. Then choose Use illustrative scenario in the Θ panel.

    Cells
    23,959
    Iterations
    1,126
    Run time
    about 4 min
    Open VirchueBio X →
  3. 3 · Hard

    A branching artery

    Open the Blood-vessel library in panel 1, choose Carotid bifurcation, keep the suggested mesh and press Run. A branching vessel needs far more work: this run stopped at the default limit of 2,000 iterations before it reached the tolerance, so the app marked Θ as exploratory. You don’t have to wait for the limit: press Stop at any point to look at the results so far, then Run to continue.

    Cells
    83,845
    Iterations
    2,000 (limit)
    Run time
    about 45 min
    Open VirchueBio X →

After that, bring your own vessel: prepare a vessel from an STL, or extract one from a DICOM scan, and follow the same steps.

Run times were measured in Chrome on a 2-core, 2.1 GHz cloud computer in November 2026. They are a guide: your computer may be faster or slower, and a finer mesh takes longer. The app shows the time taken when each run ends. Keep the tab in front while a run is going, because browsers slow down tabs in the background.

How it works

From a patient's vessel to its thrombogenic hotspots

ForgeFlow simulates how blood moves through the vessel. The FGT model turns those flow results into indexes such as the Thrombosis Number Θ, showing where clots could start under the conditions you set.

01 / 04

Patient geometry

A branching artery with a narrowing, segmented from a scan

Schematic illustration: the vessel, flow and Θ values are illustrative. FGT results are exploratory model outputs that depend on the inputs; they are not a clinical prediction.

  1. 01

    Patient geometry

    Start from a patient's CT or MR angiogram: VirchueBio extracts the vessel from the DICOM scan, or you load a fluid-lumen STL. Its inlet and outlets are named during vessel preparation.

  2. 02

    Blood flows in

    Set the inflow and blood properties. Blood enters the vessel, speeds up through narrowings and slows into recirculation behind them.

  3. 03

    Rapid CFD with ForgeFlow

    ForgeFlow meshes the vessel and solves the blood flow, showing progress and convergence while it runs.

  4. 04

    FGT indexes such as Θ

    The flow results feed the FGT model, which maps indexes such as the Thrombosis Number Θ over the vessel wall and flags spots above the reference value Θ = 1 as possible thrombogenic spots under the given conditions.

In the app

Six steps for your own case

  1. 01

    Extract the vessel from DICOM

    Drop the CT or MR angiography series into DICOM vessel extraction; it builds the vessel surface in millimetres. Already have an STL? Load it in vessel preparation instead.

  2. 02

    Prepare the vessel

    Confirm its units, check the detected openings and assign inlet or outlet roles, then select Use in ForgeFlow.

  3. 03

    Set the flow inputs

    Enter the inlet flow as a flow rate, mean velocity or shear rate, with density, viscosity and boundary conditions.

  4. 04

    Generate the mesh

    Follow the mesh guidance and inspect the geometry and openings.

  5. 05

    Run and inspect flow

    Watch progress and convergence; unfinished flow stays explicitly exploratory.

  6. 06

    Map thrombosis number Θ

    Choose the Θ inputs in the first results panel. Θ is calculated on the vessel wall and shown in 3D; save the report and wall values.

The science

Built on Force-Gated Thrombosis

FGT is our theory of how blood flow forces can initiate a clot. It treats clot initiation as a force-gated transition and defines a dimensionless Thrombosis Number, Θ, that separates stable flow from clot growth. The platform applies it to patient-specific vessels.

Preprint

Liu X, Chen Y, Zhuang MS, Vigolo D, Yong K-T. Force-Gated Thrombosis (FGT): A Non-Equilibrium Mechanical Theory of Shear-Induced Blood Clot Initiation. bioRxiv, 2026. doi:10.64898/2026.05.17.725779

Please cite this paper when you publish results produced with VirchueBio.

Read the paper
Research use only

Know what a result means

Thrombosis maps are exploratory model quantities under the inputs you enter. They are not calibrated patient risk estimates or a prediction that a clot will form, and the platform is not a medical device.

Terms of use · Privacy policy

  • Separate checks, shown separatelyImport, meshing, flow convergence and the thrombosis calculation are reported as distinct stages.
  • Your results, your filesExports are saved as files on your computer. Nothing is sent to us unless you press Submit to VirchueBio.
  • Keep the contextShare results with their units, boundary conditions, parameters and convergence status.

Questions, ideas or a case to discuss?

Join the VirchueBio community to ask questions, report problems and suggest features, or contact the team about collaboration.