Extract the vessel
Drop a CT or MR angiography series (DICOM). The vessel is found slice by slice, bone and organs are removed, and its surface is built in millimetres, all in your browser.
VirchueBio X v3.0 Free research beta · What’s new in v3.0
Drop in a CT or MR angiogram (DICOM): VirchueBio extracts the vessel, simulates its blood flow and shows where the vessel wall is most exposed to clot-promoting forces. Already have a vessel surface? Load its STL instead. VirchueBio X is a research platform from a University of Sydney team, free to use in your browser. Its rapid CFD module, ForgeFlow, solves the blood flow.
New here? The demo takes a built-in example from geometry to thrombosis number Θ in about a minute. Chrome or Edge on a desktop or laptop. Watch the getting-started video.
See the whole workflow
A one-minute tour of the five steps, from dropping in a DICOM scan to the Θ map. The example is a synthetic scan, and run times depend on the vessel.
What the platform does
Four stages, each with its own checks, so you can see how far a result can be trusted before you share it.
Drop a CT or MR angiography series (DICOM). The vessel is found slice by slice, bone and organs are removed, and its surface is built in millimetres, all in your browser.
Review the extracted vessel, or import a fluid-lumen STL or a lumen with named caps. Confirm its units, review every opening and assign inlet and outlet roles.
Set flow and blood properties, generate a mesh with patient guidance and run a flow simulation with live progress and convergence checks. You can also let the vessel wall expand and recoil with each heartbeat (vessel wall motion).
Compute the team's force-based thrombosis indices on the simulated flow, inspect them in 3D and export fields, figures and case records.
Start here
New to the platform? Work through three built-in cases in order. Each takes longer than the one before, so you know what to expect before you run a vessel of your own.
One click. The demo takes a pipe with a 50 % narrowing from geometry to thrombosis number Θ on a coarse mesh, and explains each step as it goes.
Do each step yourself. Choose Pipe stenosis in panel 1, set the mesh to 30,000 target cells in panel 2, generate the mesh and press Run. Then choose Use illustrative scenario in the Θ panel.
Open the Blood-vessel library in panel 1, choose Carotid bifurcation, keep the suggested mesh and press Run. A branching vessel needs far more work: this run stopped at the default limit of 2,000 iterations before it reached the tolerance, so the app marked Θ as exploratory. You don’t have to wait for the limit: press Stop at any point to look at the results so far, then Run to continue.
After that, bring your own vessel: prepare a vessel from an STL, or extract one from a DICOM scan, and follow the same steps.
Run times were measured in Chrome on a 2-core, 2.1 GHz cloud computer in November 2026. They are a guide: your computer may be faster or slower, and a finer mesh takes longer. The app shows the time taken when each run ends. Keep the tab in front while a run is going, because browsers slow down tabs in the background.
How it works
ForgeFlow simulates how blood moves through the vessel. The FGT model turns those flow results into indexes such as the Thrombosis Number Θ, showing where clots could start under the conditions you set.
01 / 04
Patient geometry
A branching artery with a narrowing, segmented from a scan
Schematic illustration: the vessel, flow and Θ values are illustrative. FGT results are exploratory model outputs that depend on the inputs; they are not a clinical prediction.
Start from a patient's CT or MR angiogram: VirchueBio extracts the vessel from the DICOM scan, or you load a fluid-lumen STL. Its inlet and outlets are named during vessel preparation.
Set the inflow and blood properties. Blood enters the vessel, speeds up through narrowings and slows into recirculation behind them.
ForgeFlow meshes the vessel and solves the blood flow, showing progress and convergence while it runs.
The flow results feed the FGT model, which maps indexes such as the Thrombosis Number Θ over the vessel wall and flags spots above the reference value Θ = 1 as possible thrombogenic spots under the given conditions.
In the app
Drop the CT or MR angiography series into DICOM vessel extraction; it builds the vessel surface in millimetres. Already have an STL? Load it in vessel preparation instead.
Confirm its units, check the detected openings and assign inlet or outlet roles, then select Use in ForgeFlow.
Enter the inlet flow as a flow rate, mean velocity or shear rate, with density, viscosity and boundary conditions.
Follow the mesh guidance and inspect the geometry and openings.
Watch progress and convergence; unfinished flow stays explicitly exploratory.
Choose the Θ inputs in the first results panel. Θ is calculated on the vessel wall and shown in 3D; save the report and wall values.
The science
FGT is our theory of how blood flow forces can initiate a clot. It treats clot initiation as a force-gated transition and defines a dimensionless Thrombosis Number, Θ, that separates stable flow from clot growth. The platform applies it to patient-specific vessels.
Force-Gated Thrombosis (FGT): A Non-Equilibrium Mechanical Theory of Shear-Induced Blood Clot Initiation. bioRxiv, 2026. doi:10.64898/2026.05.17.725779
Please cite this paper when you publish results produced with VirchueBio.
Read the paperThrombosis maps are exploratory model quantities under the inputs you enter. They are not calibrated patient risk estimates or a prediction that a clot will form, and the platform is not a medical device.
Join the VirchueBio community to ask questions, report problems and suggest features, or contact the team about collaboration.