Prepare a vessel, simulate its blood flow and explore where the vessel wall is most exposed to clot-promoting forces. VirChue Bio X is a research platform from a University of Sydney team, free to use in your browser. Its rapid CFD module, ForgeFlow, solves the blood flow.

New here? The demo takes a built-in example from geometry to thrombosis number Θ in about a minute. Start with vessel preparation for your own STL. Chrome or Edge on a desktop or laptop. Watch the getting-started video.

  • Research use onlyExploratory model results, not a medical device or a clinical risk score.
  • Your files stay with youGeometry and simulations are processed in your browser; nothing is uploaded unless you submit it.
  • Visible numerical statusMesh quality and flow convergence are shown alongside every result.

What the platform does

One workflow, from geometry to wall loading

Three stages, each with its own checks, so you can see how far a result can be trusted before you share it.

01 — Geometry

Prepare the vessel

Import a fluid-lumen STL or a lumen with named caps, confirm its units, review every opening and assign inlet and outlet roles.

02 — Flow

Simulate blood flow

Set flow and blood properties, generate a mesh with patient guidance and run a flow simulation with live progress and convergence checks.

03 — Thrombosis

Explore thrombosis maps

Compute the team's force-based thrombosis indices on the simulated flow, inspect them in 3D and export fields, figures and case records.

Start here

Three cases, from one minute to 45 minutes

New to the platform? Work through three built-in cases in order. Each takes longer than the one before, so you know what to expect before you run a vessel of your own.

Getting started · 2 min 46 s · no sound, captions on screenRecorded on VirChue Bio X v1.0
  1. 1 · Easy

    Run the demo

    One click. The demo takes a pipe with a 50 % narrowing from geometry to thrombosis number Θ on a coarse mesh, and explains each step as it goes.

    Cells
    6,638
    Iterations
    607
    Run time
    about 1 min
    Run the demo →
  2. 2 · Medium

    The same pipe, step by step

    Do each step yourself. Choose Pipe stenosis in panel 1, set the mesh to 30,000 target cells in panel 2, generate the mesh and press Run. Then choose Use illustrative scenario in the Θ panel.

    Cells
    23,959
    Iterations
    1,126
    Run time
    about 4 min
    Open VirChue Bio X →
  3. 3 · Hard

    A branching artery

    Open the Blood-vessel library in panel 1, choose Carotid bifurcation, keep the suggested mesh and press Run. A branching vessel needs far more work: this run stopped at the default limit of 2,000 iterations before it reached the tolerance, so the app marked Θ as exploratory. You don’t have to wait for the limit: press Stop at any point to look at the results so far, then Run to continue.

    Cells
    83,845
    Iterations
    2,000 (limit)
    Run time
    about 45 min
    Open VirChue Bio X →

After that, bring your own vessel: prepare a vessel from an STL and follow the same steps.

Run times were measured in Chrome on a 2-core, 2.1 GHz cloud computer in November 2026. They are a guide: your computer may be faster or slower, and a finer mesh takes longer. The app shows the time taken when each run ends. Keep the tab in front while a run is going, because browsers slow down tabs in the background.

How it works

From a patient's vessel to its thrombogenic hotspots

ForgeFlow simulates how blood moves through the vessel. The FGT model turns those flow results into indexes such as the Thrombosis Number Θ, showing where clots could start under the conditions you set.

01 / 04

Patient geometry

A branching artery with a narrowing, segmented from a scan

Schematic illustration: the vessel, flow and Θ values are illustrative. FGT results are exploratory model outputs that depend on the inputs; they are not a clinical prediction.

  1. 01

    Patient geometry

    Start from a patient's vessel: a fluid-lumen STL segmented from CT or MRI, with its inlet and outlets named during vessel preparation.

  2. 02

    Blood flows in

    Set the inflow and blood properties. Blood enters the vessel, speeds up through narrowings and slows into recirculation behind them.

  3. 03

    Rapid CFD with ForgeFlow

    ForgeFlow meshes the vessel and solves the blood flow, showing progress and convergence while it runs.

  4. 04

    FGT indexes such as Θ

    The flow results feed the FGT model, which maps indexes such as the Thrombosis Number Θ over the vessel wall and flags spots above the reference value Θ = 1 as possible thrombogenic spots under the given conditions.

In the app

Six steps for your own case

  1. 01

    Load the fluid lumen

    Drop an STL, a lumen with named cap STLs, or its folder into vessel preparation, then confirm its units.

  2. 02

    Review every opening

    Check the detected openings, assign inlet or outlet roles, then select Use in ForgeFlow.

  3. 03

    Set the flow inputs

    Enter the inlet flow as a flow rate, mean velocity or shear rate, with density, viscosity and boundary conditions.

  4. 04

    Generate the mesh

    Follow the mesh guidance and inspect the geometry and openings.

  5. 05

    Run and inspect flow

    Watch progress and convergence; unfinished flow stays explicitly exploratory.

  6. 06

    Map thrombosis number Θ

    Choose the Θ inputs in the first results panel. Θ is calculated on the vessel wall and shown in 3D; save the report and wall values.

The science

Built on Force-Gated Thrombosis

FGT is our theory of how blood flow forces can initiate a clot. It treats clot initiation as a force-gated transition and defines a dimensionless Thrombosis Number, Θ, that separates stable flow from clot growth. The platform applies it to patient-specific vessels.

Preprint

Liu X, Chen Y, Zhuang MS, Vigolo D, Yong K-T. Force-Gated Thrombosis (FGT): A Non-Equilibrium Mechanical Theory of Shear-Induced Blood Clot Initiation. bioRxiv, 2026. doi:10.64898/2026.05.17.725779

Please cite this paper when you publish results produced with VirChue Bio.

Read the paper
Research use only

Know what a result means

Thrombosis maps are exploratory model quantities under the inputs you enter. They are not calibrated patient risk estimates or a prediction that a clot will form, and the platform is not a medical device.

Terms of use · Privacy policy

  • Separate checks, shown separatelyImport, meshing, flow convergence and the thrombosis calculation are reported as distinct stages.
  • Your results, your filesExports are saved as files on your computer. Nothing is sent to us unless you press Submit to VirChue Bio.
  • Keep the contextShare results with their units, boundary conditions, parameters and convergence status.

Questions, ideas or a case to discuss?